r/buildingscience • • Jan 19 '21

Reminder Of What This Sub Is All About

94 Upvotes

Hey everyone,

There's been a bit of spam in the mod queue lately and I figured it'd be useful to touch base and remind folks what this space is really all about.

It's not a job board or a place to promote building products (unless you're talking about some brand new membrane dehumidification product that nobody's ever seen before). It's not a place to have people help you figure out how to unlock a door. It is a place to discuss questions about how products work or fail, field techniques, research literature, adjacent relevant fields of research, and field practices. Remember that this is a unique science subreddit in that we occupy the space between research, manufacturing, and field reality. We are one of the best examples of applied science out there. So let's think about content through that lens. Let's share things that advance the conversation and help people take their learning to a deeper level. All are welcome, just don't spam pls.


r/buildingscience • • Jan 26 '23

Building Science Discord

Thumbnail
discord.gg
9 Upvotes

r/buildingscience • • 3h ago

Triple glazing with only 2 panes of glass? 🪟

Thumbnail
reddit.com
0 Upvotes

r/buildingscience • • 11h ago

Question How to find companies that use Zip sheathing and tape for resheathing?

0 Upvotes

I am doing new Hardie siding next year and having a hard time finding companies around here that use Zip sheathing and tape as an option for resheathing.

I don't like searching with Google because of AI, and I don't know how to find a siding or other company who is willing to offer Zip sheathing as an option. Please give me ideas. Also I'd appreciate info on how to know if people know what they're doing with Zip sheathing and tape (questions to ask them, red flags to look out for, whether or not to get the work inspected as it goes on and by who?) This is my first house and I want it done right and I don't want to get ripped off. I'm making sure to get a Certificate of Insurance and business license from every company with a quote. No COI or proof of license means no moving forward with them.

I don't trust Google or Yelp reviews, because anyone can write anything they want good or bad about any company, without using their real name. Is asking for X number of references or to visit a jobsite where they're working so I can see how it's done, out of line?

Are there building science/"Zip experts" who do "in process" or "after installation" inspections to make sure the Zip and taping is done right? I don't have the expertise to be able to look at it as it's being done or after and say, "Stop/slow down/there's a mistake here/etc." Or is there usually a project manager/foreperson on the job who walks around and makes sure everyone is doing a solid job?

The sheathing will be exposed while waiting for new windows to be installed, so I want to make sure it's done right. It's a box shaped ranch house with a 3-4 foot wide brick fireplace bumpout on the back side as the only obstacle to work around.


r/buildingscience • • 1d ago

Question What is the origin of this dust?

Thumbnail gallery
0 Upvotes

r/buildingscience • • 2d ago

Would you spray foam a house ?

7 Upvotes

Hello. Would you spray foam a house that already has a zip system installed on the outside? I think rockwool insulation would be more than enough for the walls and I worry spray foam leads to issues. Thoughts ? Thanks


r/buildingscience • • 2d ago

Help picking window material for my climate

2 Upvotes

I need to get new windows for my house. My zip falls into California climate zone 3 and ASHRAE/IECC zone 3C. I'm not sure what kind of window material will be best suited for my climate and give the best longevity.

I'm leaning towards fiberglass ext/wood int windows from Marvin but I see a number of brands have aluminum/wood windows available while the fiberglass exterior, wood interior seems pretty much exclusive to Marvin.


r/buildingscience • • 2d ago

Replacing conventional vents (holes in the walls capped with a grill), with modern mechanical ventilation. Does this cause meaningful savings in heat energy loss?

0 Upvotes

My report that came with a heat evaluation cert mentioned ventilation heat loss is 34.96 W/K.

The next greatest source of heat loss are the external walls at walls at 32.79 W/K, and then windows/glazing (total glazed heat loss) at 15.79 W/K

My ventilation is currently a series of holes in the walls with an open/shut grill placed over them.

The rooms are also highly prone to mould.

I understand mechanical ventilation can improve air flow whilst avoiding heat loss, is this true?

External walls are by far the worst source of heat loss according to my report, but cutting out heat loss through the ventilation system would cause a heat-retention improvement equivalent to negating heat loss through the walls?

Does that sound right?

Seems excessive or overly optimistic.


r/buildingscience • • 2d ago

Question Best way to address high humidity behind cinder block walls in basement? Would soil grading and fixing gutters/downspouts really fix issues?

Thumbnail reddit.com
1 Upvotes

r/buildingscience • • 3d ago

Question Rope rescue and open web.

Post image
3 Upvotes

I saw a video of some training a FD was doing that got me thinking about open web metal truss and their feasibility for rescue rigging and point loads. Does anyone work with metal truss’ that has any knowledge of or where i can find info on this? I saw something that was vague about the steel joist institute recommending no more than a 100 pound point load on the bottom truss. I do work in the rescue field which is why i would like some clarification on this. A lot of the time we just say hey its structural metal it’s fine.


r/buildingscience • • 3d ago

Question How much positive pressure is too much for cathedral ceiling venting?

Thumbnail reddit.com
0 Upvotes

Please see my post on r\roofing related to a tricky attic ventilation question. Thanks


r/buildingscience • • 3d ago

Title: Cold first floor, stuffy upstairs every winter. Who’s actually fixed their stack effect?

Thumbnail reddit.com
0 Upvotes

r/buildingscience • • 3d ago

Proper venting for double roof attic

Thumbnail gallery
2 Upvotes

r/buildingscience • • 4d ago

Rim joist insulation on older home - is a little bit enough or is it best to max out?

Thumbnail reddit.com
1 Upvotes

Reposting here since the building science sub just came to my attention. I always enjoy hearing from thinky people who build.


r/buildingscience • • 4d ago

1920s Attic Insulation with HVAC in unconditioned space.

Thumbnail gallery
1 Upvotes

Would you use closed cell spray foam in this 1920s attic in Maryland? There is an HVAC unit in this unconditioned space.


r/buildingscience • • 4d ago

Question Waterproof Old Basement Slab?

1 Upvotes

1950s home with typical slab. Unfortunately, it was painted at some point and that of course never adhered well due to moisture and the slab itself crumbles in spots. It's fine for an unfinished space but needs to be properly sealed before I finish the basement. The rear of the home is a walkout and have considered both exterior and interior drain along front of the home, just for as much moisture management as possible. We are on a ridge though so it's mostly just natural clay soil moisture we have. No bulk water issue.

Anyhow, I was considering a few options:

  1. Dimple mat adhesive and taped seams, including around the entire slab up to the CMU wall. The goal being that the moisture is completely stopped from migrating up from slab, don't want that leaking from sides where it hits wall either. I am thinking the dimple mat air space itself still provides a better capillary break. But I can't imagine it doesn't become completely wet/humid... Equilibrium with the slab and soil though? And don't see it actually "drying" in any way and if the outter else left open it's just opportunity for moisture (and mold) to release into air. I'll seal it off entirely.

Then adavantech subfloor floated. Flooring over that. All completed floating. Nothing securing through the dimple mat. I don't think I'll bother with foam under subfloor.

2. Liquid applied waterproof membrane. This would require some sort removal of my painted subfloor and don't want to do that. But perhaps this would be more reliable than the dimple mat? But I don't know if dimple mat provides a better moisture and capillary break? Not sure if the science but the air gap of dimple mat and not having to rely on the membrane adhesion is better. This saves some space but simple mat isn't that tall.

3. Some plastic vapor barrier and concrete poured over the top. Then subfloor and flooring. I'd still do it all floating but this is most expensive and also tallest since I suspect concrete would need to be at least 2" if not more? And I'd admittedly fear subfloor directly on this concrete, though maybe that's unfounded. Since I have the vapor break under it.

Any advice on each? Which is preferred? Science behind? Pros / cons? Other options?

The CMU wall I'm going to just leave gap behind when I install my walls. For one, leaves space for running some utilities but also ensures I have complete air flow for drying and the entire space has dehumidifying and will pull returns in that make sure ever separate space draws out the air.


r/buildingscience • • 4d ago

ERV for large homes

0 Upvotes

I am building a 12000sqft 8 bedroom home. Per ASHRAE 62.2 I need about 430cfm continuous. The only ERVs that will satisfy this at the mid of their capacity are Lifebreath ERV 1230 or RenewAire HE10IN. I am concerned about constant noise from either of these 2 units. Unfortunately the house is ICF and I dont have any way to make 10" holes in concrete so I can only make 2 openings in the wood framed opening on the 2nd floor. The ERV will be mounted in mudroom on Main/First floor. Lifebreath doesnt have any sound data on its commercial models while RenewAire has high DB sound data. Just wondering what did those who have 5000+ sqft homes do to resolve the sound issue?


r/buildingscience • • 5d ago

I think I created a triple moisture barrier (facepalm)

Thumbnail gallery
4 Upvotes

r/buildingscience • • 5d ago

Vaulted ceiling insulation strategy for 1960s house

Thumbnail
gallery
13 Upvotes

I'm renovating a 1961 mid century modern inspired split level house that I purchased recently and have not moved into yet. It had original acoustic tiles glued to the drywall of the living room vaulted ceiling that were ugly so we tore the whole ceiling out. The house is fully insulated with 1960's fiberglass bats, the original version that has no R value printed on them and are only 2-3 inches thick at best and definitely less than R10. Obviously we should replace the ceiling insulation and air seal while it's open, but I'm struggling with the best way to do it.

We are in climate zone 5a with hot humid summers and variable winters that can be cold and snowy.

The rafters are only 2x6's, which is why there is a beam supporting them in the center. That doesn't leave a lot of room for insulation. The roof has 2ft overhangs/eaves all around that are open into the living space, and have a vent in them. This roof continues up over the upstairs bedrooms to form a gable, but there is no ridge or gable vents. The roof shingles were replaced in 2018 and solar panels were added to this vaulted section a few years ago, so adding any exterior insulation is impractical at this time. It's also impractical to fur out the rafters to add more depth as the ceiling isn't that high; the point where I took the second picture from at the railing the floor to ceiling height is only 80".

Initially I was thinking of using Rockwool bats in the cavities with a smart vapor retarder on the inside, but that only gets R23. Our GC is recommending closed cell spray foam that is sprayed about 4" thick and can achieve R34 and air seal as well. Initially I was concerned about closed cell spray foam from both the environmental and off gassing issues perspective. Is it the best way to solve this problem?

We will also insulate the attic area adjacent to this section of roof, but for that the GC is recommending to blow in insulation over the room ceilings and not spray foam under the roof deck. We would air seal what we can before adding the insulation.


r/buildingscience • • 4d ago

Going from 1.0 to 0.1 ACH50 might save us only $15/month. What else makes it worthwhile?

Thumbnail reddit.com
1 Upvotes

r/buildingscience • • 5d ago

If I air seal my attic and rim joists, do I have to replace the boiler in my basement?

Thumbnail reddit.com
1 Upvotes

r/buildingscience • • 5d ago

If I air seal my attic and rim joists, do I have to replace the boiler in my basement?

Thumbnail reddit.com
0 Upvotes

r/buildingscience • • 5d ago

IWI vapour-open systems

Thumbnail reddit.com
1 Upvotes

r/buildingscience • • 5d ago

Pole Barn / Woodshop Insulation

Thumbnail gallery
2 Upvotes