r/PLC • • Oct 07 '26

[READ FIRST] Ask your career questions here! Want to get into PLC's? Are you an electrician, maintenance tech, CS graduate, looking to learn? Start here!

63 Upvotes

READ FIRST: How to learn PLC's and get into the Industrial Automation World

Ask your questions below! The thread is sorted by New, so the latest questions are at the top. Thread will stay open indefinitely.

Feel free to visit:


r/PLC • • 26d ago

PLC jobs & classifieds - Nov 2026

19 Upvotes

Rules for commercial ads

  • The ad must be related to PLCs
  • Reply to the top-level comment that starts with Commercial ads.
  • For example, to advertise consulting services, selling PLCs, looking for PLCs

Rules for individuals looking for work

  • Don't create top-level comments - those are for employers.
  • Reply to the top-level comment that starts with individuals looking for work.
  • Feel free to reply to top-level comments with on-topic questions.

Rules for employers hiring

  • The position must be related to PLCs
  • You must be hiring directly. No third-party recruiters.
  • One top-level comment per employer. If you have multiple job openings, that's great, but please consolidate their descriptions or mention them in replies to your own top-level comment.
  • Don't use URL shorteners. reddiquette forbids them because they're opaque to the spam filter.
  • Templates are awesome. Please use the following template. As the "formatting help" says, use two asterisks to bold text. Use empty lines to separate sections.
  • Proofread your comment after posting it, and edit any formatting mistakes.

Template

**Company:** [Company name; also, use the "formatting help" to make it a link to your company's website, or a specific careers page if you have one.]

**Type:** [Full time, part time, internship, contract, etc.]

**Description:** [What does your company do, and what are you hiring people for? How much experience are you looking for, and what seniority levels are you hiring for? The more details you provide, the better.]

**Location:** [Where's your office - or if you're hiring at multiple offices, list them. If your workplace language isn't English, please specify it.]

**Remote:** [Do you offer the option of working remotely? If so, do you require employees to live in certain areas or time zones?]

**Travel:** [Is travel required? Details.]

**Visa Sponsorship:** [Does your company sponsor visas?]

**Technologies:** [Required: which microcontroller family, bare-metal/RTOS/Linux, etc.]

**Salary:** [Salary range]

**Contact:** [How do you want to be contacted? Email, reddit PM, telepathy, gravitational waves?]


Previous Post:


r/PLC • • 10h ago

Homework Che emozione

Thumbnail
gallery
79 Upvotes

È emozionante vedere quanta storia c’è stata nel progresso degli anni.

Sono del ‘99 e sono abituato a TIA e simatic, se sbaglio qualcosa il programma me lo fa notare, qui sono poco fiducioso😂😂.

Eppure c’erano queste bellezze!
Immagino a chi utilizzava pc del genere quante parolacce sono state dette quando si sbagliava qualcosa 😂😂.

Chi di voi ha avuto esperienze in passato?


r/PLC • • 1h ago

Engineering Question VM's for Programming Laptop

3 Upvotes

This is the first time I have a need for a VM as most of the software I have is on a Windows 10 machine and our company wants to migrate to Windows 11 where I am one of the last hold outs. For me to transition the software to Windows 11 would require software upgrades/patches and licenses for many machines.

I was hoping for those who use VM's, you can tell me why you choose what you did such as Virtual Box, Microsoft Hypervisor etc. and maybe a simple reason why as I am hoping this will reduce my learning curve and get me up running as quickly as possible.

Thanks for your responses!


r/PLC • • 11h ago

PLC Question How do you manage version control and track changes in PLC projects written in Ladder Logic?

13 Upvotes

Hi everyone,

I'm looking for advice on how other companies manage version control for PLC software.

At the company I currently work for, we develop PLC software mainly using Ladder Logic in Siemens TIA Portal (V14–V21) and Rockwell Studio 500 / Studio 5000.

Our current version control method is fairly basic: whenever a software change is made, we archive the project with the date, time, and name of the software engineer. The previous version is then moved into the "Old" folder of that project.

This works for keeping backups, but it has some major limitations:

  • We cannot easily compare two versions to see exactly what has changed.
  • It is difficult to track changes made by different engineers.
  • Firmware versions and other project configuration changes are not always clearly documented.
  • Finding out why or when a specific change was made can be time-consuming.

I've looked into using Git, but it doesn't seem to work particularly well with PLC projects developed in Ladder Logic, especially when it comes to comparing changes in a meaningful way.

I'm interested in hearing what other companies are using for version control in PLC development.

Some questions:

  • What tools or methods do you use to manage PLC project versions?
  • Are there any tools that allow you to properly compare changes in Ladder Logic?
  • Do you use dedicated PLC version control software, Git-based workflows, or something else?
  • How do you keep track of firmware versions and hardware configuration changes?

We have also discussed moving towards Function Block programming or Structured Text to make version control easier. However, my colleagues have been working with Ladder Logic for 20+ years and are understandably more comfortable with it.

Personally, I'm comfortable working with Ladder, Function Blocks, and Structured Text, so I'm open to different approaches. Ideally, though, we'd like to improve our version control without having to completely change our programming methods.

What are your experiences and recommendations?

Thank you for your time!

i have been looking into copia, if people have experiences with that i would like to know as well


r/PLC • • 8h ago

Career Question Learning PLC programming on your own

6 Upvotes

Hello all.

I currently work in the automation business and am looking to expand my knowledge when it comes to PLC programming. Does anyone have any recommendations on where to start?

I've expressed my interest among coworkers and management but nobody has the time to show me or train me. Not to mention, I'm in the hardware design department and they can't afford to take me away from that at the moment.

All advice is welcomed. Appreciate you!


r/PLC • • 12h ago

PLC Question Comunicação Industrial

Post image
11 Upvotes

Ajuda dos universitários: como tirar dados de CLPs de segurança sem acesso à rede OT?

Trabalho numa multinacional que tem alguns CLPs de segurança da SICK (Flexi Soft). Consegui visualizar e extrair as variáveis, e agora quero montar uma dashboard com indicadores simples (estado da máquina, paradas, causas etc.).

O problema é que a empresa não libera o Wi-Fi da rede OT. Tentei usar LoRa com um Raspberry Pi + ESP32, mas o sinal ficou bem ruim: cerca de -84 dBm a uns 200 m, e a fábrica fica a 500–600 m de onde os dados precisam chegar. Além disso, os equipamentos são desmontados com frequência, então não dá para deixar cabo de rede nem montar repetidores pelo caminho.

Os colegas mais antigos usam um roteador industrial com chip 4G e uma instância na AWS para receber os dados. Alguém tem outra sugestão? Abaixo está a arquitetura que eu desenhei antes de levar um balde de água fria da TI.


r/PLC • • 11h ago

PLC Question Vijeo Designer 6.2 : Runtime-created users wiped on Ethernet download despite "Retain Runtime Data"

3 Upvotes

Hi everyone,

I'm running into an issue with Vijeo Designer 6.2 SP12 (Runtime 6.2.12 Build 2054) on a Magelis HMIGTU setup (HMIG3U box + HMIDT732 display) and hoping someone has seen this before.

The issue:

Operators and admins create new users and passwords directly on the HMI during runtime using the native User Manager. Whenever I make a minor graphical change on my PC and download the project to the HMI over Ethernet, all runtime-created users are wiped after reboot, reverting back to the default users defined in the offline project.

Setup details:

- Software / Runtime: Vijeo Designer 6.2 SP12 (Build 2054)

- Hardware: HMIG3U + HMIDT732 (HMIGTU series)

- Project origin: Initially uploaded from the HMI via Upload Editor Project (.vdz)

- Security architecture: Security Data is set to Use Common Settings with Client / Server = Server on this HMI

What I have already checked:

- SRAM battery test: A user created on the HMI survives a 30-second 24V power cycle with no PC connected, so the SRAM backup battery is fine.

- Target > General: Retain Runtime Data is checked.

- Retain Runtime Data (...) dialog: Security Settings, Recipe, and Target System Settings are all checked, and Delete all runtime data is unchecked.

- Build process: I never use Clean All and I never touch Environment > Security in the editor, just save and download over Ethernet.

Why is the runtime security table still getting overwritten on Ethernet download? Is this a known quirk when Security Data is set to Client / Server (Server) with [Common] settings?

Is there any native way to retain or back up/restore these encrypted runtime users on an HMIG3U without storing passwords in plain text (like CSV recipes)?

Thanks in advance for any insight!


r/PLC • • 14h ago

PLC Question Siemens changes of TIA Portal upgrade

3 Upvotes

Since a week Siemens released TIA Portal version 21.1. Instead of the 'expected' version 22.
Then I looked into it and found that they are going to change quite a bit.

Sales and delivery release: TIA Portal V21.1

Continuous access to new software: Siemens ends project upgrades in TIA Portal within the V21 line

Has anybody got already some experience with it?


r/PLC • • 1d ago

Career Question Is EPLAN required for entry level jobs?

15 Upvotes

Heyy guys!!

I recently started my PLC automation journey. I’ve been learning new skills and usage of different tools. I’m confused whether to include EPLAN in my skillset. So, can any working professionals here guide me regarding this? I’m trying to enter PLC field as an entry level engineer. Also, I heard that i must have the skill of reading the schematics, not drawing them.

So, I thought reaching out here would give me some clarity. Also, if there are any other gold standard skills or tools worth learning, let me know!
Thank you!


r/PLC • • 1d ago

PLC Question Omron and Siemens

5 Upvotes

After Learning Siemens Tia Portal how easy is to master Omron?


r/PLC • • 1d ago

PLC Question Always upload plc project before monitoring?

15 Upvotes

Just wondering what's considered good practice when it comes to going online to monitor a plc. Either opening the latest project file before going online vs always transferring to the PC first so you're guaranteed to have the latest version (in this case there's only 1 workstation used to connect to the PLC).


r/PLC • • 2d ago

PLC Question Touch screen not functioning on Schneider Electric HMISBC (HMIS85)

Thumbnail
gallery
12 Upvotes

Hi everyone! I was given this PLC with HMI combo thing (I never tried going into the PLC world but I wanted to start trying), the only problem is that the touch screen does not work, I have no idea what could possibly have been the problem, the person who gave this to me said that he tried this panel on another PLC (dunno if it was fully functioning or not) and the screen wasn't working correctly on it but the touchscreen did (same model, maybe different hw revision), he said he also tried another panel on this PLC and (if he remembered correctly) said that it works but the touch does not, the HMI panel that I have only had a bent pin that was carefully put back in place without any problems, I have tried everything, I even tried opening the PLC up and redoing the solder joints on the HMI connector but nothing changed! Anything I should try next? Also the configuration menu won't work, touchscreen is dead dead.


r/PLC • • 1d ago

Career Question Software dev in manufacturing (Oracle ERP / custom MES) looking to learn Omron CJ1M/CJ2M. Where to start?

3 Upvotes

Hey everyone,

I’m a software developer currently working in manufacturing, and I’m looking to cross over into the controls side of the house, specifically learning Omron PLCs (CJ1M and CJ2M).

My Background:

  • CS degree, 3 years work experience as an enterprise web app developer for a maufacturing site.
  • Experienced with Oracle ERP and various database systems.
  • Hands-on experience building and maintaining a custom MES / manufacturing data collection system end-to-end (modern web tech, database design, and ETL).
  • Decent grasp of how data moves on the plant floor once it leaves the machine, though I’m a total beginner when it comes to ladder logic, hardware wiring, and PLC programming.
  • Decent understanding of system designs and networking.
  • My Setup: I only have Windows 11 machines at both home and work.

What I’m Looking For:

  1. Where to start: Given that our plant uses Omron CJ1M/CJ2M, what software (CX-Programmer / CX-One?) and hardware setups should I focus on first? Are there specific manuals, YouTube channels, or courses you recommend for older/legacy Omron gear?
  2. Most efficient path: Since I already kinda understand programming logic, state machines, and data types, how can I leverage my software background to pick up ladder logic and Omron’s memory mapping (DM, CIO, W, etc.) without wasting time on absolute beginner programming concepts?
  3. Timeline & Reliability: Honestly, I don’t consider myself a smart person, just someone who puts in the work. Realistically, how long does it take to get to a point where I can reliably troubleshoot, read logic, and make safe, minor edits without breaking production? Are there any specific Omron certifications or credentials worth getting, or is hands-on experience all that matters in this field?

THANK YOU ALL!


r/PLC • • 1d ago

Career Question Suggest me what can I do to improve

3 Upvotes

I am currently studying electrical engineering in a collage 4 -2 sem , i learned some plc course on like siemens , mitsubishi and delta plcs and HMI

can anyone suggest me what to do next


r/PLC • • 3d ago

Meme When TIA freezes after you opened the wrong menu

685 Upvotes

r/PLC • • 2d ago

Engineering Question ABB robot 50056 error joint collision. HELP!

Thumbnail
gallery
35 Upvotes

We are experiencing an issue with the rotational axes of a positioner.

When we try to jog the axes from the FlexPendant, we can hear the motors running, but the positioner only moves about 2 degrees before triggering ABB error 50056 – Joint Collision.

This error occurs when the measured torque on a specific robot joint exceeds the expected torque commanded by the motion controller.

However, when we manually press the brake release buttons, the table moves freely on both axes.

So far, we have replaced the servo drive in the controller and also replaced the power cable running from the motor to the brake release panel.

After restarting the power supply to the servo motors, we were able to jog one of the axes using the FlexPendant, but we are not sure what caused this.

However, after restarting the controller again, we lost the ability to move that axis once more.

We are currently replacing the SMB cable, after which we will proceed with recalibrating the positioner.

I hope this turns out to be the root cause of the problem.

Any advice or suggestions would be greatly appreciated.


r/PLC • • 2d ago

PLC Question TIA v17 online/offline compare issue

Post image
7 Upvotes

Hi, I’m trying to make a small change to a plc project, but when I do an online/offline compare with the latest project I have, I get this where it says some FBs and DBs only exist offline, then the same FBs and DBs only exist online?

Will it be ok to download the project to the PLC as the timestamps match?

Any help would be great


r/PLC • • 2d ago

PLC Question Help - Need 1 Year of Historian Data

10 Upvotes

Looking at a SCADA application that needs to historize data for 1 year in a database. I originally was planning to use Ignition Edge but unfortunately they only let you store up to 35 days of data with no add-on option. The project doesn't warrant a full Ignition package, what other basic SCADA software can handle the historian feature that won't break the bank? Background is just one PLC connection and the gateway will be on a Server hosted by the customer.


r/PLC • • 2d ago

Career Question Is $83K a good starting salary for a remote job (entry-level) with 75% travel?

66 Upvotes

I already accepted the job but I decided to post this anyways to see what you guys are making or hear your thoughts on this. I was initially offered $81K (salary), but I successfully countered the offer to $83K. This is a remote job with positive Indeed reviews, flexible PTO, 10 paid holidays, and 70% travel.

For context, I have a degree in Electrical Engineering. Right out of college, I started my first job at $75K in 2021 at a paper company without any work experience. I was there for 1 year before deciding to join the Marines. Four years later, I left the Marines with a salary of $94k. I'm taking a huge pay cut with this new job but my current priority is to build my technical experience and stay in this industry permanently. I have no intentions on going back to the military nor reserves. I'm also a single guy with no pets and used to the "pack your bags up we gotta go" lifestyle.


r/PLC • • 2d ago

PLC Question IFM IO-Link slave block communication and TIA Portal

3 Upvotes

EDIT: It was indeed the byte size. It needed an 8-byte instead of 4-bytes. However, in comparison to another program, the inputs do not line up. I10.0 was the start of inputs in the old program and block, but the new block (in old program) is starting at I12.0. The new block is a 10 port block so now i understand why it needed to go to 8-bytes. But I figured the inputs would still line up. Diagnostic and status would be the last half of the address group.

Does an IO-Link device need much configuration after making the port it’s connected to “IO-Link”?

I have an IFM master block talking to an S7-1500. The program is from another project, so the configuration is already there for the masterblock. I configured the block in TIA portal. It shows port 1 is set for an IO-Link device. But when I plug in a slave IFM block, the io-link light on the master block flashes red, TIA portal shows port 1 green (odd) and the slave block shows green. Only the masterblock flashes red. Also, using Moneo (IFM configuration app) it will not see the slave block.

Do I need to do something in TIA portal to get this to work?

I am (at least was) heavy Rockwell and this is my first Siemens project. I’ve also been out of this game for about 5 years and IO Link is somewhat new to me.


r/PLC • • 2d ago

Engineering Question Formatter for Structured Text

6 Upvotes

I need to consult the hive-mind here.

Does anybody have a good formatter for Structured Text (dialect is secondary). I need it to be able to properly indent multiple commented lines as, unfortunately, the original creator of the programs (a lot) has decided to disable certain parts with the (# and #) comments and yet uses the (* and *) comments in between the outer comments.

I've inherited this program (which is quite huge) and need to sift through it. Can't just simply omit/delete the commented out code as it is absolutely possible that it will be used at any given time in the future.

The original creator didn't want to think about a mechanism to disable certain parts (each part reflects a particular "Control Unit").

I would be very grateful for any recommendation. My google-fu and my VSCode extension search didn't bring decent results.

Edit: I cannot use any AI as assistant because of the sensitivity of the data. This is also the reason I have to be so vague here in my descriptions. (The bane of working in system-critical infrastructure.)


r/PLC • • 2d ago

Homework wago hmi / plc users?

7 Upvotes

I've been investigating security on some systems. Some things are harder to root than others. My wago plcs and hmis were exceedingly simple to root. But, then again, they're 10 years old, so, I'm not sure if the issues Ive observed are present in more modern systems.
I'd like to ask anyone with more modern Wago plcs and HMIs, to report output from 1 command, from an unprivileged ssh account. I'd like to know model/ year release, and the output of $sudo -l

for my own curiosity, I want to see if privilege escalation avenues are still a default setup in more modern implementations.


r/PLC • • 2d ago

Engineering Question PyAds with html interface or Beckhoff HMI with html hosts?

6 Upvotes

I am currently working on a project which requires a lot of html, js and css elements like the canvas element for displaying robot positions and adjusting timelines. At the moment i am using the twincat hmi server with visual studio code to write what is basically a website with the lay-out: twincat .view with a .htmlhost and then the page written in there.

The only thing i am using the twincat hmi for is the live view (needed because of the framework) and the ads communication.

Are there any benefits to using the twincat hmi server with twincat plc or would a PyAds server with twincat plc work just as well? Are there any future support issues to take into account?

From what i'm seeing, PyAds would be just fine as we are not using any beckhoff HMI elements like buttons/graphs, but only the htmlhost to run the code. But i feel like i'm missing something in regards to benefits the twincat server would have over a PyAds server.

Can anybody tell me what other support i would be missing?


r/PLC • • 2d ago

PLC Question TIA Portal V20 Openness e Python.NET

3 Upvotes

TIA Portal V20 Openness – How to configure WinCC Unified encrypted transfer settings?

Hi everyone,

I'm developing an engineering automation tool using TIA Portal V20 Openness with Python.NET.

I'm trying to programmatically configure the following WinCC Unified HMI settings:

  • Activate encrypted transfer
  • Password and password confirmation
  • Allow initial password transfer via unencrypted download

These settings are located under Runtime settings → General.

I've already investigated the public API using reflection, engineering attributes, services and HmiRuntimeSetting properties, but couldn't find the corresponding API members.

I successfully created an HMI from a Master Copy using:

project.Devices.CreateFrom(masterCopy)

However, I would prefer to configure these settings directly instead of maintaining separate templates for every HMI model and firmware version.

Has anyone successfully accessed these settings through Openness V20 or V21?

Is there an undocumented attribute, supported engineering service or alternative approach?

Any C# or Python examples would be greatly appreciated.

Thanks!